Bioz Stars score: 86/100, based on 1 PubMed citations. In combination with our unique NANOTRAC FLEX, the particle size can also be measured as a sixth parameter simultaneously in the same sample. The concept of zeta-potential has been used for more than a century as a basic parameter in controlling the stability of colloidal suspensions, irrespective of the nature of their particulate ingredients organic or inorganic. Otsuka Holdings zeta potential dynamic light scattering analyzer Zeta Potential Dynamic Light Scattering Analyzer, supplied by Otsuka Holdings, used in various techniques. Regarding the optimized measurement technology, the STABINO ZETA can measure up to 5 parameters simultaneously and within a few seconds: Zeta potential, streaming potential, conductivity, pH value, and temperature. The instrument also has the capacity of zeta potential detection by Phase Analysis Light Scattering (PALS) measurements for samples with low mobilities. It is possible to measure the zeta potential of particles in the range of 0.3 nm to 300 µm in a concentration range of up to 40 volume percent. It is the force that maintains the discreteness of the billions of circulating cells, which nourish the organism. The STABINO ZETA has a high resolution and data point density, which allows very fast, precise and reproducible zeta potential measurements. Colloidal system dynamic light scattering microelectrophoresis INTRODUCTION Zeta Potential represents a basic law of Nature, and it plays a vital role in all forms of plant and animal life. These parameters have established as a typical measure representing the electrostatic repulsion between particles. Nowadays, particle surface charge and interface potentials, such as the zeta potential and the streaming potential, are widely used to characterize the stability of suspensions, emulsions and nanoparticles. Dynamic light scattering (DLS) measures the time dependent fluctuations in the scattering intensity to determine the translational diffusion coefficient. It can replace the classical zeta potential measurement and is able to perform very fast titrations. The systems measure size using dynamic light scattering, zeta potential using electrophoretic. Particles from less than a nanometer in size to several microns can be analyzed by a range of variants. For the accurate determination of the zeta potential and colloidal stability, the STABINO ZETA is the first choice. The Malvern Zetasizer provides exceptionally high performance that incorporate combinations of a particle size analyzer, zeta potential analyzer.